3 machine operation, Getting started, 3 machine operation -2 – JLG 10MSP Operator Manual User Manual
Page 30: Getting started -2, 10msp - machine operating specifications -2

SECTION 3 - MACHINE OPERATION
3-2
– JLG Lift –
3121227
3.3 MACHINE OPERATION
Getting Started
The following control conditions must be met before the machine
can be operated from either the Ground or Platform Controls:
• Batteries contain enough voltage to operate. Low Battery
warning not indicated on Ground Control Station.
• The Main Power Selector Switch on the Ground Control Sta-
tion must be set for either Ground Control Mode or Platform
Control Mode.
• Platform Control Console On/Off Power Switch (Key) must
be set to ON.
• Both Emergency Stop Switches, Ground and Platform Con-
trol must be in the RESET position (out).
• The Machine Status LCD Screen on the Ground Control Sta-
tion indicates normal operating conditions when machine is
powered up.
• Both platform swing-in entry gates must be closed to operate
machine.
Figure 3-1. 10MSP - Machine Operating Specifications
GRADEABILIT
Y
LEVEL
DO NOT DRIVE MACHINE ON GRADES EXCEEDING
THOSE SPECIFIED IN SECTION 5 - MACHINE SPECIFICATIONS
SIDESLOPE