Code 33 - reserved, Code 34 - auxiliary #2 - inhibit, Code 35 - auxiliary #2 - tie down – JLG SSV10 Service Manual User Manual
Page 117: Code 36 - reserved, Code 37 - reserved, Code 34 - auxiliary #2 - inhibit -25, Code 35 - auxiliary #2 - tie down -25, See table 6-32, Ge 6-25, See table 6-33
SECTION 6 - TROUBLESHOOTING
3121187
– JLG Lift –
6-25
Code 33 - RESERVED
Code 34 - Auxiliary #2 - Inhibit
Check For These Obvious Conditions First:
• Open Platform Gate.
• No Pressure on the Platform Footswitch.
Code 35 - Auxiliary #2 - Tie Down
Check For These Obvious Conditions First:
• Pressure on the Platform Footswitch during machine power up.
Code 36 - RESERVED
Code 37 - RESERVED
Table 6-32. Code 34 - Auxiliary #2 - Inhibit
STEP
ACTION
SPEC
YES
NO
1.
At the Ground Control Module, P1 connector, check the voltage
across pins-8 and 1 to the Aux. #2 component. Is reading within
specification?
0 - 2V DC
Go to Step 2
Replace Ground
Control Module
2.
Remove the wire terminals at the Aux. #2 component, check conti-
nuity of each of the wires from pins-8 and 1 on the P1 connector to
the Aux. #2 component end.
—
Replace the
Component
Repair or
Replace Wiring
Table 6-33. Code 35 - Auxiliary #2 - Tie Down
STEP
ACTION
SPEC
YES
NO
1.
At the Ground Control Module, P1 connector, check the voltage
across pins-8 and 1 to the Aux. #2 component. Is reading within
specification?
0 - 2V DC
Go to Step 2
Replace Ground
Control Module
2.
Remove the wire terminals at the Aux. #2 component, check conti-
nuity of each of the wires from pins-8 and 1 on the P1 connector to
the Aux. #2 component end.
—
Replace the
Component
Repair or
Replace Wiring