5 software level 2 accessibility, 1 operator tools, 2 personalities – JLG 723A Service Manual User Manual
Page 113: 3 calibrations, Software level 2 accessibility, Operator tools, Personalities, Calibrations

9.5
L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7
Electrical System
9.5
SOFTWARE LEVEL 2 ACCESSIBILITY
The following parameters can be altered in the 2nd level of access to the machine’s software.
Refer to Section 9.17.2, “Analyzer Software - Version 3.5,”for detailed software information.
9.5.1
Operator Tools
9.5.2
Personalities
9.5.3
Calibrations
Function
Description
Change Anti Theft
Code
Allows the owner to change the Anti Theft Code
Perform Hardware
Exchange
Allows the owner to restore machine data (anti theft code, engine hours, machine
personalities, etc.) in the event that the machine controller or display/cluster gauge has
been replaced
Confirm Machine
Service
Allows the owner to turn off the Service Required Warning lamp when service is
performed
Review Service History
Allows the owner to see the last 15 times the Service Required Warning lamp was reset
Set Service Interval
Allows the owner to modify the default service interval of 100 hours
Cabin Joystick
Telescope: X-Axis/
Roller
Allows the owner to change/swap operation of the joystick Telescope and Fork Tilt
functions.
Function
Description
Default Value
Main Lift
Allows the owner to adjust the Max Lift Up & Max Lift Down function speeds
1400 mA
Soft Lift
Allows the owner to adjust the derate value when the boom enters the soft lift
zone
40%
Telescope
Allows the owner to adjust the Max Tele In & Max Tele Out function speeds
1450 mA (out)
1350 mA (in)
Fork Tilt
Allows the owner to adjust the Max Fork Tilt Up & Max Fork Tilt Down function
speeds
1350 mA (up)
1450 mA (down)
Aux.
Function
Allows the owner to adjust the Accel, Decel, and Max Function A & Max
Function B function speeds
1550 mA
Aux.
Momentary
Allows the owner to adjust the Max Momentary Aux A & Max Momentary Aux B
function speeds
1100 mA
Bucket
Mode
Allows the owner to adjust the Max Bucket Up & Max Bucket Down function
speeds
65 mA
Function
Description
Boom Angle
Allows the owner to calibrate the boom angle sensor if it is replaced. Refer to Section 9.14.10,
“Boom Angle Sensor.”