3 safety, 1 intended use, 2 user profile – Eppendorf Concentrator plus (New Design) User Manual
Page 14: 3 application limits, 2 maximum service life for accessories, Safety 3.1, Intended use, User profile, Application limits 3.3.1, Maximum service life for accessories

Concentrator plus/Vacufuge® plus — Operating manual
14
3
Safety
3
Safety
3.1
Intended use
Concentrator plus and Vacufuge plus are intended for sample preparation. The device may only
be operated by trained specialist staff.
Concentrator plus and Vacufuge plus are intended for interior use only and mainly intended for
the concentration of aqueous solutions of nucleic acids and proteins in approved sample tubes.
3.2
User profile
This device may only be operated by correspondingly trained specialist staff. This staff must have
carefully read the operating manual and be familiar with the function of the device.
3.3
Application limits
3.3.1
Declaration concerning the ATEX directive (94/9/EC)
Due to their current design and the environmental conditions on the inside of the device, the
Concentrator plus / Vacufuge plus are not suitable for use in a potentially explosive atmosphere.
The device must therefore only be used in a safe environment, such as in the open environment
of a ventilated laboratory or an extractor hood. The use of substances which may contribute to a
potentially explosive atmosphere is not permitted. The final decision with regard to the risks
connected with the use of such substances is the responsibility of the user.
3.3.2
Maximum service life for accessories
The maximum service life for plastic adapters is 1 year from first commissioning. Do not use the
adapter beyond this period!
For the rotors (see Rotors on p. 11) described here there is no limit for their service life, as long
as the following conditions are met: proper use, recommended maintenance and undamaged
condition.
CAUTION!
Poor safety due to incorrect accessories and spare parts.
The use of accessories and spare parts other than those recommended by Eppendorf may
impair the safety, function and precision of the device. Eppendorf cannot be held liable or accept
any liability for damage resulting from the use of incorrect or non-recommended accessories and
spare parts or from the improper use of such equipment.
Only use accessories and original spare parts recommended by Eppendorf.
CAUTION!
Continuous delivery can affect safe operation of the device.
When delivering liquids continuously, membranes and valves of the vacuum pump can be
damaged.
Only use the device for applications of limited duration.
DANGER!
Danger of explosion!
Do not operate the device in areas where work is completed with explosive substances.
Do not use this device to process any explosive or highly reactive substances.
Do not use this device to process any substances which could create an explosive
atmosphere.
EN