Starting From Platform Control Box

Before you begin to operate the ATB 42/50 from
the platform control box, a qualified operator
must perform the “Daily Inspection and
Maintenance” as described in chapter 7.

To start the engine from the platform control box
do the following:

1. Set the Battery switch (1) in turntable to ON.

2. Set the Emergency Stop switch (2) at the

ground controls to ON (pulled out).

3. Set the Platform/Ground Selector switch on

the platform control box to PLATFORM (up).

4. Insert the key (3) and set the Master Key

Switch (4) to ON.

5. For LPG fuel operation: Completely open the

valve (5) on top of the LPG tank, (turn
counterclockwise until it stops).

6. Enter the platform, close the gate (6), and

attach the lanyard of your fall restraint to one
of the anchor points (7).

page 8 - 4