Level sensor 7-10, Emergency power 7-10, Platform box switches and alarms 7-10 – Snorkel ATB50 CE User Manual
Page 56: Emergency power, 7-10, Level sensor, 7-10, Adanger

s
Level Sensor
Use Riser Lift to raise the platform about six feet
(2 m). With the Master Key Switch and the
Emergency Stop switch (at the ground) ON, pull
the level sensor to the side as far as possible.
The tilt alarm should sound.
The level sensor is located in the left side of the
turntable, behind the ground control box.
s
Emergency Power
A
DANGER
When you check turntable Swing at CCW (1)
the turntable will move directly toward you. Be
sure you have room to step backward.
Check each of the seven platform moving
switches (2), using Emergency Power (3), to see
that they work correctly. Check both positions of
each switch (2).
For correct emergency power operating procedures
see “Emergency Operation” chapter 9.
Check each of the boom movement functions
from the platform control box, using Emergency
Power. Check all positions of each control.
s
Platform Box Switches and Alarms
Check all of the platform moving, drive, and
steering functions from the platform control box to
see that they cause the ATB 42/50 to move the
way it should.
For correct operating procedures see the
“Operation” chapter 8.
Pay particular attention to the Emergency Stop
switch to see that it turns the ATB 42/50 engine
off when struck.
Pay particular attention to the platform foot switch
to see that it deactivates the platform moving
switches when the foot switch is not stepped on.
page 7 - 10
ATB 42/50 – 0161987EE
7. Daily Inspection and Maintenance