beautypg.com

Flashing lights 7-9, Air filter 7-9, Charging system 7-9 – Snorkel AB50JRT User Manual

Page 56: Ground control switches and alarms 7-9, Charging system, 7-9, Air filter, 7-9, Filter minder gauge, 7-9, Flashing lights, 7-9, Flashing, 7-9, Daily inspection and maintenance

background image

Platform Box Switches and Alarms

Check all of the platform moving, drive, and
steering functions from the platform control box to
see that they cause the AB50J to move the way it
should.

For correct operating procedures see the
“Operation” chapter 8.

Pay particular attention to the Emergency Stop
switch to see that it turns the AB50J engine off
when struck.

Pay particular attention to the platform foot switch
to see that it deactivates the platform moving
switches when the foot switch is not stepped on.

Operator Horn

Press the operator horn (if the AB50J has that
option) to see that it works.

Motion Warning Alarm

Listen for the motion warning alarm (if the AB50J
has that option) as you drive forward and
backward. Listen for the start up alarm when the
Anti-Restart Switch is first turned ON.

Ground Fault Circuit Interrupt

Connect the power input connector (at the rear of
the turntable) to a source of 125 volt AC, 15 A
electrical power.

If the AB50J is equipped with the optional AC
generator, connect the power input connector
to the AC generator, start the engine, then set
the AC Generator switch to ON.

1. Push the TEST button (1) IN on the GFCI.

The RESET button (2) should pop OUT.

2. Press the RESET button (2) back IN. Set the

AC Generator switch to OFF if you used the
optional AC generator.

AB50J – 0163189

page 7 - 11

7. Daily Inspection and Maintenance