1. Put the base plate onto the pump head, so
that the boreholes “T” and “P” of the base
plates matches with the ports of the pump
head
Take care, that the surfaces are clean and
dust-free.
2. Put the 4 screws into the designated
boreholes and tighten them with a torque
of 20 Nm.
3. When you are connecting the hose assemblies directly to the hand pump, you will have
to mount appropriate designated couplings, fittings or closing screws to the ports “P” and
“T”. (tightening torque M
A
= 40 Nm)
6.2 Base plates
ATTENTION!
After the end of the assembly close all hydraulic lines by using closing screws
and/or dust protection caps, to prevent the hand pump from impurities.