Mounting of base plates and valve blocks 6 – Lukas LH2 User Manual
Page 10

10
2-way-distribution
valve N2W
841489903
2,1
Distribution valve to divide
one oil flow into two flows.
By closing or opening the
valve screw, the partial
flows could be regulated
and harmonized.
(Base plate is a basic
requirement)
Oil distributor with
pressure gauge
connection N4M
841489905
1,4
By use of the oil distributor
one oil flow can be divided
into 5 flows. The distributor
has 4 pressure ports
(G1/4”) and one pressure
gauge port (G1/4”).
(Base plate is a basic
requirement)
Mounting of base plates and valve blocks
6.
ATTENTION!
When mounting base plates and valve blocks, hydraulic fluid can leak from
the pump. To make sure that the quantity of the leaking fluid is as small as
possible, the hand pump should be in a vertical position with the hydraulic
ports facing upwards, while mounting base plates and valve blocks
Make sure to store all plugs, screw plugs and/or dust caps in a way that
prevents them from getting dirty or lost.
Especially you will have to take care that the eventually leaking hydraulic fluid
is being collected completely and being disposed professionally!