Harness – Class1 Digital Display User Manual
Page 4
![background image](/manuals/546733/4/background.png)
4
The digital displays are connected to the OEM harness with a Deutsch 8 pin mini-
connector.
Mating Connector:
DTM06-08S
Locking Wedge
WM-8S
Mating Terminal:
0462-201-20141
20 gauge socket
General Terminal Assignments:
1)
Alarm Output (Ground)
2)
Primary Pressure Signal
3)
Sensor Supply (+ 5 or +10 VDC)
4)
System Power (+ 12 VDC)
5)
System Ground
6)
Sensor Ground
7)
Signal (frequency or secondary PSI in)
8)
Test, Total or Alarm Switch (Ground)
Not all of the digital displays use all of the terminals.
See individual display pages for application specific information.
Harnesses are available for the digital displays in various lengths.
These include transmitter/transducer and power connections.
Harness Part Numbers by length and application.
5’
10’
20’
30’
Flowmeter Display
102064
102033
102065
103165
Pressure Display
102060
102035
102061
102271
Breathing Air Display
102670
102671
102672
Oxygen System Display “
“
“
Tank Level Display
102193
102194
102195
102729
Dual Transducer
102439Y
102455
Speedometer
102242
102243
102244
DC Voltmeter
“
“
“
Dual Display “Y”
102294
102295
Dual Current Amplifier
103318
Display Pigtail
102272
Extension 15’
103367
Harness
1
2
3
4
8
7
6
5
Wire Insertion View