Tank Level

Basic Calibration:

(2 point)

With the fluid tank empty, enter the
calibration password.

L L L R R R

The left (0%) bar will flash to indi-
cate that you are ready to calibrate
for an empty tank.
Activate the left switch followed by
the right switch.
The right (100%) bar will flash to
indicate that the display is ready to
calculate for a full tank.
When the tank is full, actuate the
right and then the left switch.

Calibration is complete.

If after checking the accuracy of
your calibration, you are not satis-
fied, you can perform the advanced
calibration procedure. This is rarely
necessary except in the case of
oddly shaped tanks.

Advanced Calibration: (5 point)

With the fluid tank empty, enter the
calibration password.

L L R R L L

The left (0%) bar will flash to indi-
cate that you are ready to calibrate
empty.
Activate the left switch followed by
the right switch.
The fifth bar from the left (25%) will
flash to indicate that the display is
ready to calculate for a quarter tank.
Fill the tank to 1/4 full, actuate the
right and then the left switch.
The tenth bar from the left (50%)
will flash to indicate that the display
is ready to calculate for a half tank.
Fill the tank to 1/2 full, actuate the
left and then the right switch.
The fifteenth bar from the left (75%)
will flash to indicate that the display
is ready to calculate for three fourths
tank.
Fill the tank 3/4 full, actuate the right
and then the left switch.
The right (100%) bar will flash to
indicate that the display is ready to
calculate for a full tank.
When the tank is full, actuate the
right and then the left switch.

Calibration is complete.