Digital Speedometer calibration is performed with the vehicle speed stabilized at 40 M.P.H.
or (40 K.P.H. )

The calibration mode is entered by the use of a “password”.
There are two magnetic switches, one located at each side of the display.
These switches are activated with the use of a magnet. Switch activation is visually
confirmed by the lighting of the closest decimal point on the display.
Enter the switch sequence below to enter calibration mode.

L L L R R R

Left Switch

Left Switch

Left Switch

Right Switch

Right Switch

Right Switch

If the password is correctly entered, “

CAL

” will be displayed for 1/2 second followed by

40

Maintain a constant speed of 40 for a minimum of 10 seconds to assure an accurate and
stable calibration before activating the left switch.

Activate the left switch.

The display will read “

donE

and return to normal operation showing the current speed.

Calibration is now complete.