10-2860 B Series COP Instructions RevB 111117
KIT CONTENTS
1 x 35-2840 IGNITER W/ BRACKET
1 x 30-3255 HONDA EPM
4 x 30-2850 COIL
1 x 35-3860 B SERIES COP HARNESS
1 x 35-3861 EPM HARNESS
2 x #6 MOUNTING SCREW
2 x DIELECTRIC GREASE
INSTALLATION TIPS
1. Read through the entire manual and instructions before beginning the
installation.
2. Disconnect the negative battery cable(s) before beginning any work.
3. Maintain a clean and neat work area throughout the installation.
4. When raising or working under a vehicle, use properly rated stands/jacks.
5. Make sure all connectors are fully seated and inserted.
6. Make sure all components and cables are routed and installed away from any
direct heat sources or sharp objects.
TABLE OF CONTENTS
• Installation
2
• EMS/ECU Configuration 8
• Jumper Settings
12
• Syncing The EMS Timing
17
• EMS Pin Locations
18
• Connector Pinouts
19
• Factory Tachometer Setup
20
• Specifications
21
• Recommended Parts
21
• Replacement Parts
21
• Warranty
22
INSTALLATION
Removing the Factory Ignition
Remove the spark plug wires from the distributor and cylinder head. Unplug the
distributor from the factory wiring harness and remove the distributor from the engine.
The distributor is held in place by three mounting bolts. See Figure 1 below.