AEM 30-2860 Coil-On-Plug COP Conversion Kit User Manual
Page 18
Page 18
10-2860 B Series COP Instructions RevB 111117
EMS Pin Locations
Relevant pin locations for the 30-6040, 30-6050, and 30-6060 Series 2 EMS units are
shown below in Table 4.
PIN
EMS 30-6040
EMS 30-6050
EMS 30-6060
EPM
Harness
COP
Harness
Coil 1
A21
C4
A20
NA
Orange
Coil 2
B6
C12
B7
NA
Blue
Coil 3
B3
C13
B9
NA
Pink
Coil 4
B4
C14
B10
NA
Grey
Cam
B11
C29
C4
White
NA
Crank
B15
C8
C2
Green
NA
Pwr Gnd
A23 A24 A26 B2
B2 B10 B20 B22
A9 A10 A22 A23
Drain
NA
SW +12
A25 B1 C1
A21 B9
A11 A24 C6
Red
NA
Snsr Gnd
D21 D22
A7 A31 C7 C18 D9
D11 D12 D13
Black
NA
Relevant pin locations for the 30-1040, 30-1050, and 30-1060 Series 1 EMS units are
shown below in Table 5. Take notice that the Series 1 EMS units use the #5 coil driver
on cylinder 4. The Series 2 EMS units use the #4 coil driver on cylinder 4.
PIN
EMS 30-1040
EMS 30-1050
EMS 30-1060
EPM
Harness
COP Harness
Coil 1
A21
B13
A20
NA
Orange
Coil 2
B6
C12
B7
NA
Blue
Coil 3
B3
C13
B9
NA
Pink
Coil 5
B4
A1
B19
NA
Grey
Cam
B11
C29
C4
White
NA
Crank
B15
C8
C2
Green
NA
Pwr Gnd
A23 A24
B2 B10 B20 B22
A9 A10 A22 A23
Drain
NA
SW +12
A25 B1 C1
A21 B1 B9
A11 A24 C6
Red
NA
Snsr Gnd
A26 B2 D21 D22 A7 A31 C7 C18 D9
D11 D12 D13
Black
NA
Table 4. Series 2 EMS Pin Locations