I

NFRARED

/R

ADIANT

C

OMPACT

B

ROILER

I

NSTALLATION

& O

PERATIONS

M

ANUAL

1186529 R

EV

3 (12/06)

P

AGE

19

OF

24

S

ERVICE

WARNING

ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO IS
EXPERIENCED IN, AND KNOWLEDGEABLE OF, THE OPERATION OF COMMERCIAL COOKING
EQUIPMENT. TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR
RELIABLE SERVICE, DEPENDABLE ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY
PARTS.

NOTICE

INSTALLATION OF OTHER THAN GENUINE BLODGETT RANGE RANGE PARTS WILL VOID THE
WARRANTY ON THIS EQUIPMENT.

The serial plate is located under the broiler bottom drip pan at the front, toward the left (see Figure 1 on page 3).
Replacement parts (including parts not listed in this manual) may be ordered either through a Blodgett Range
Authorized Parts Distributor or a Blodgett Range Authorized Service Agency.
When ordering parts, please supply the Model Number, Serial Number, Part Number, and Part Description.

T

ROUBLESHOOTING

Problem

Look for -

Not enough heat

– Low pressure in gas supply

– Restriction in gas piping and/or valves

– Misalignment of burner orifice tube

– Clogged burner orifice

– Incorrect burner orifice

Too much heat

– Incorrect orifices

– Defective or incorrectly set pressure regulator

Burner flame has excessive blue haze

– Obstruction of combustion-air intake on rear of broiler

– Exhaust gases blocked by objects sitting on top of broiler

– Low pressure in gas supply

– Misalignment of orifice tube

Burner flame fluttering

– LOW setting of burner valve out of adjustment

Burner flame popping (Infrared)

– Cracked or loose ceramic

Slow burner ignition

– Pilot flame out of adjustment

– Pilot alignment out of adjustment

Pilot outage

– Pilot flame out of adjustment

– Draft condition

– Pilot orifice clogged

– Incorrect pilot orifice