Caution, Emergency operations – SkyTrak 6036 Operation Manual User Manual
Page 89

Emergency Operations
83
Model 6036
4. Position the towing vehicle in place. Attach any chains needed to
secure the disabled vehicle.
5. Attach a remote portable hydraulic pressurizing unit to the parking
brake gauge port (Figure 53, 1) on the secondary function manifold
(2) mounted on the inside wall of the frame (3) on the left side next
to the transmission.
Figure 53
6. Turn the key switch to the ON position (with the engine not run-
ning), release the park brake switch, and have an operator seated
in the seat.
7. Pressurize the park brake with the pressurizing unit. Close the
pump needle valve
CAUTION:
DO NOT exceed 575 psi (40 bar) when pressur-
izing the park brake. Applying too much pressure may damage
the brake seals.
2
OA1230
Front
1
3