D6 (DIO6 Configuration)
Command
The D6 command
is used to select/read the behavior
of the DIO6 line (pin 16).
Options include:
• RTS flow control
• Analog-to-digital
converter
• Digital input
• Digital output
D7 (DIO7 Configuration)
Command
The D7 command
is used to select/read the behavior
of the DIO7 line (pin 12).
Options include:
• CTS flow control
• Analog-to-digital
converter
• Digital input
• Digital output
D8 (DI8 Configuration)
Command
The D8 command
is used to select/read the behavior
of the DI8 line (pin 9).
This command enables configuring
the pin to function as a digital
input. This line is also used
with Pin Sleep.
AT Command: ATD6
Parameter Range:0 - 5
Parameter Configuration
0
Disabled
1
RTS Flow Control
2
n/a
3
DI
4
DO low
5
DO high
Default Parameter Value:0
Parameters 3-5 supported as of firmware
version 1.xA0
AT Command: ATD7
Parameter Range:0 - 5
Parameter Configuration
0
Disabled
1
CTS Flow Control
2
n/a
3
DI
4
DO low
5
DO high
Default Parameter Value:1
Parameters 3-5 supported as of firmware version
1.x.A0
AT Command: ATD8
Parameter Range:0 - 5 _ (1, 2, 4 & 5 n/a)
Parameter Configuration
0
Disabled
3
DI
Default Parameter Value:0
Minimum Firmware Version Required: 1.xA0