CA (CCA Threshold) Command
set and read CCA (Clear Channel
Assessment) thresholds.
Prior to transmitting a packet, a CCA is
performed to detect energy on the transmit
channel. If the detected energy is above
the CCA Threshold, the RF module will not
transmit the packet.
CC (Command Sequence Character)
Command
CC command is used to set and read
the ASCII character used
between
guard times of the AT Command Mode
Sequence (GT + CC + GT). This sequence enters the RF module into AT Command
Mode so that data entering the module from the host is recognized as commands
instead of payload.
The AT Command Sequence is explained further in the AT Command Mode section.
CE (Coordinator Enable) Command
used to set and read the behavior (End
Device vs. Coordinator) of the RF module.
AT Command: ATCA
Parameter Range: 0 - 0x50 [-
dBm]
Default Parameter Value: 0x2C
(-44 decimal dBm)
Minimum Firmware Version
Required: v1.x80
AT Command: ATCC
Parameter Range: 0 - 0xFF
Default Parameter Value: 0x2B (ASCII
“+”)
Related Command: GT (Guard Times)
AT Command: ATCE
Parameter Range:0 - 1
Parameter Configuration
0
End Device
1
Coordinator
Default Parameter Value:0
Minimum Firmware Version Required:
v1.x80