I/O Settings
DIO6 Configuration. Select/Read
settings for the DIO6 line (pin 16)
of the RF module. Options include
RTS flow control and I/O line
settings.
0 – 1
0 = Disabled
1 = RTS flow
control
2 = (n/a)
3 = DI
4 = DO low
5 = DO high
0
D5 (v1.x80*)
I/O Settings
DIO5 Configuration. Configure
settings for the DIO5 line (pin 15)
of the RF module. Options include
Associated LED indicator (blinks
when associated) and I/O line
settings.
0 – 1
0 = Disabled
1 = Associated
indicator
2 = ADC
3 = DI
4 = DO low
5 = DO high
1
D0 - D4
(v1.xA0*)
I/O Settings
(DIO4 -DIO4) Configuration.
Select/Read settings for the
following lines: AD0/DIO0 (pin
20), AD1/DIO1 (pin 19),
AD2/DIO2 (pin 18), AD3/DIO3
(pin 17), AD4/DIO4 (pin 11).
Options include: Analog-to-digital
converter, Digital Input and Digital
Output.
0 – 1
0 = Disabled
1 = (n/a)
2 = ADC
3 = DI
4 = DO low
5 = DO high
0
IU (v1.xA0*)
I/O Settings
I/O Output
Enable.Disables/Enables I/O data
received to be sent out UART.
The data is sent using an API
frame regardless of the current
AP parameter value.
0 – 1
0 = Disabled
1 = Enabled
1
IT (v1.xA0*)
I/O Settings
Samples before TX.Set/Read the
number of samples to collect
before transmitting data.
Maximum number of samples is
dependent upon the number of
enabled inputs.
1 - 0xFF
1
IS (v1.xA0*)
I/O Settings
Force Sample.Force a read of all
enabled inputs (DI or ADC). Data
is returned through the UART. If
no inputs are defined (DI or ADC),
this command will return error.
8-bit bitmap (each
bit represents the
level of an I/O line
setup as an
output)
-
IO (v1.xA0*)
I/O Settings
Digital Output Level.Set digital
output level to allow DIO lines that
are setup as outputs to be
changed through Command
Mode.
- -
IC (v1.xA0*)
I/O Settings
DIO Change
Detect.Enables/Disables the
monitoring of the change detect
feature on DIO lines 0-7. If a
change is detected, data is
transmitted with DIO data only.
Any samples queued and waiting
for transmission will be sent first.
0 - 0xFF [bitfield]
0
(disabled)