background image

2000 Series | Program Entry Guide | 11.0

Point Codes

EN | 45

Bosch Security Systems | 7/05 | 35114F

11.4 Digit 4, Device Address

Digit 4 is not required for E version control panels. E version control panels only include the On-board points,
and they ignore Point Code Digit 4.

Digit 4 tells the system what device a point is connected to. Digit 5 tells the system the sensor loop on the
device. The control panel’s On-board points are numbered 1 to 6. Leave Digits 4 and 5 at their default setting
(“0” for Digit 4, “A” for Digit 5) for on-board sensor loops. If you program a point number less than 6 to a
point expander, the system ignores the control panel’s on-board sensor loop for that point.

For example, to make Point 5 a motion detector connected to loop D of a D222 Text Keypad with Address 7,
set the

Address 7

prompt in the Address Configuration Group and Digits 4 and 5 of the point code as follows:

Address 7 = Text Keypad with points

Digit 4 = 7

Digit 5 = D (motion detector wired to loop D of the D222 Text Keypad)

The control panel ignores the on-board sensor loop for Point 5.

Although eight addresses are available, you can only connect four devices with point expansion to the
control panel’s data terminal.

Points with Digit 4 set to an address not programmed for a point expander do not generate Alarm,
Trouble, or Missing reports. Refer to Section 10.0 Address Configuration to be certain that any
address programmed in Digit 4 of a point code is programmed for a point expander.

Table 8: Digit 4 Selections

0 1 2 3 4 5 6 7 8

On-Board: Detection devices for this point are connected to one of the control panel’s on-board sensor
loops.

X

Address 1: Detection devices for this point are connected to an expansion device with Address 1.

Note:

If you are connecting a text keypad to the system, you must use Address 1.

If you connect more than one text keypad, make sure one of the keypads is set for Address 1.

X

Address 2: Detection devices for this point are connected to an expansion device with Address 2.

X

Address 3: Detection devices for this point are connected to an expansion device with Address 3.

X

Address 4: Detection devices for this point are connected to an expansion device with Address 4.

X

Address 5: Detection devices for this point are connected to an expansion device with Address 5.

X

Address 6: Detection devices for this point are connected to an expansion device with Address 6.

X

Address 7: Detection devices for this point are connected to an expansion device with Address 7.

Note:

If you are connecting a RF Point Expander to the system, it can only use Address 7 or Address 8.

X

Address 8: Detection devices for this point are connected to an expansion device with Address 8.

Note:

If you are connecting a RF Point Expander to the system, it can only use Address 7 or Address 8

.

X