background image

2000 Series | Program Entry Guide | 6.0

Open/Close

EN | 24

Bosch Security Systems | 7/05 | 35114F

Program

Exit Tone

Yes to enable the exit delay tone

and excursion tone.

Program

Exit Tone

No to disable the exit delay tone

and excursion tone.

5 No Delay

Default:

Part On

Selection: Disabled, Part On, All On, All & Part

0 Disabled

1 Part

On

2 All

On

3

All & Part

The

No Delay

prompt allows users to turn their

system on with No Entry or Exit Delay (instant
arming). If this prompt is set to Part On, users can turn
their system Part On with No Delay by pressing the [0]
key twice.

If this prompt is set to All On, users can turn their
system All On with No Delay by pressing the [9] key
twice. If this prompt is set to All & Part, users can turn
their system All or Part On with No Delay.

If this prompt is set to Disabled, users cannot turn their
system on with No Delay. Entry and exit delay are
always provided.

Selecting

Disabled for the

No Delay

prompt also

disables the Excursion feature. Refer to the

Excursion

prompt.

6 Excursion

Default:

Disabled

Selection: Disabled

All Step
Part Step
All & Part Step
All Exit
Part Exit
All & Part Exit

0 Disabled

1 All

Step

2 Part

Step

3

All & Part Step

4 All

Exit

5 Part

Exit

6

All & Part Exit

Use the

Excursion

prompt to configure the system

for either the Step Outside or Exit User features.

6.1 Step

Outside

If you enable the Step Outside feature, pressing
the [CLEAR] key at the keypad when the system
is on with No Delay starts the exit delay tone (if

Exit Tone

is programmed Yes) and bypasses all

points programmed for delay (Digit 1 of point
code = 6 or 8). The rest of the system remains on.

The tone and bypass remain until the user presses
the [CLEAR] key a second time, returning the
system to its fully on state. If a point is faulted
when the user presses the [CLEAR] key the
second time, the tone and bypass continue. The
user must either clear the fault (close the door) or
turn the system off with a passcode.

The Step Outside feature allows users to pick up
the morning paper or let the dog out without
turning the system off.

All Step: Only allows users access to the Step
Outside feature when the system is All On with
No Delay (instant).

Part Step: Only allows users access to the Step
Outside feature when the system is Part On with
No Delay (instant).

All & Part Step: Allows users access to the Step
Outside feature when either All or Part of the
system is On with No Delay (instant).