Page 19

background image

2000 Series | Program Entry Guide | 4.0

Receiver

EN | 19

Bosch Security Systems | 7/05 | 35114F

3 Non-Fire Group

Default:

0

Selection: 0 to 9, B to F

1 to 8

Non-Fire alarm from Points 1 to 24.

9 or 0

Non-Fire alarm from key A, B, or C.
Refer to Section

7.0

ABC Keys.

There are no Pulse Format versions of
the Modem II Alarm recent Close,
Alarm Cross Point, or Exit Alarm
Reports. All occur as Alarm

Reports.

The Cross Point feature creates two
point alarms. Refer to Section 11.0 Point
Codes.

4 Pt Trbl Group

Default:

0

Selection: 0 to 9, B to F

1 to 8

Trouble, Missing, Bypass, or Swinger
Bypass Reports from Fire and Non-Fire
points combined.

Multiple trouble conditions can create
duplicate Trouble Reports. For
example, a point can send a trouble for
a open sensor loop, then a trouble for
missing.

5 Restoral Group

Default:

0

Selection: 0 to 9, B to F

1 to 8

Restoral on points 1 to 24, Fire and
Non-Fire combined.

6 Closing Group

Default:

0

Selection: 0 to 9, B to F

0

Closing Report when a passcode is not
required to turn system on (refer to

Passcode

Rquired

prompt in Section

15.0 Passcodes) or a keyswitch is used.

1 to 8

Closing Report with User ID for users 1
to 8.

7 Opening Group

Default:

0

Selection: 0 to 9, B to F

0

Opening Report when keyswitch is
used, or Part On No Delay, or Part On
with delay.

1 to 8

Opening Report with User ID for users
1 to 8.

8 Cancel Group

Default:

0

Selection: 0 to 9, B to F

0

Cancel Report when keyswitch is used.

1 to 8

Cancel Report with User ID for users 1
to 8.

9 Sys Trbl Group

Default:

0

Selection: 0 to 9, B to F

1

Reports an unsuccessful attempt to connect a
remote programmer.

2

Reports an unsuccessful attempt to connect a
remote programmer.

3

The system automatically reset. Call Bosch
Security Systems if reports persist.

4 Not

used.

5 Not

used.

6

Reports missing battery.

7

Reports low battery.

8

No AC power to system. Control panel is
running on battery.

9

Communication Failure event for Phone 1.

B

Communication Failure event for Phone 2.

C

RF tamper (points or receiver).

D

RF low battery.

E

RF receiver 7 trouble.

F

RF receiver 8 trouble.