2000 Series | Program Entry Guide | 11.0

Point Codes

EN | 36

Bosch Security Systems | 7/05 | 35114F

4 Point 4

Default:

9820A

Selection:

Refer to Table 5, Table 6, Table 7, Table 8, and Table 9 for selections for each digit in the point code.

9820A

Door, No Delay

No Delay Part point. Point arms when user turns the system
Part (or All) On. Point does not start entry delay.

Reports and alarm output enabled.

Trouble on short when the system is off. Swinger bypass
enabled.

Alarm Report delay enabled.

PT4

PART/NO DLY

5 Point 5

Default:

7820A

Selection:

Refer to Table 5, Table 6, Table 7, Table 8, and Table 9 for selections for each digit in the point code.

7820A

Motion Detector

No Delay All point. Point only arms when user turns the
system All On. Point does not start entry delay and is ignored
during entry and exit delays.

Reports and alarm output enabled.

Trouble on short when the system is off. Swinger bypass
enabled.

Alarm Report delay enabled.

PT5

ALL/NO DELAY

6 Point 6

Default:

7820A

Selection:

Refer to Table 5, Table 6, Table 7, Table 8, and Table 9 for selections for each digit in the point code.

7820A

Motion Detector

Same response as

Point 5

.

PT6

ALL/NO DELAY

7 to 24 Points 7 to 24

Default:

0000A

Selection:

Refer to Table 5, Table 6, Table 7, Table 8, and Table 9 for selections for each digit in the point code.

0000A

Point Disabled
The system does not monitor disabled points.

PT##