IV-2

• Condensation on the corona unit may cause corona charge leakage.

• Condensation on the hopper gate and separation pad may cause paper feed

troubles.

If condensation has occurred, wipe the effected units or parts with a dry cloth.

If the drum unit is unpacked soon after it is moved from a cold room to a warm room,
condensation may occur inside the unit, which may cause incorrect images. Instruct the
user to allow the unit to come to room temperature before unpacking it. This will take one
or two hours.

1.2

Basic Procedure

If a malfunction or incorrect print appears, make an initial check following the basic
procedure below:

(1)

Check the error lamps following the inspection proc edure described later in
this section. If no error lamps are lit, see Section 4 for troubleshooting information.

(2)

If any defective image output is found, follow the image defect fault descriptions in
this section.