beautypg.com

12v control - tab 9 – B&K CT600 User Manual

Page 55

background image

12V Control - Tab 9

B K

&

S

B

I M P LY

E T T E R !

51

1. Zone Control:

Click one of the zone buttons A thru F to setup control settings for the desired zone.

2. Zone Control Out:

Control Out is a switchable 12VDC 200mA control voltage useful for status lights on keypads, power strips,
external amplifiers or any other voltage sensing device. The default setting of each of the individual Zone
Control Output is Zone ON - the voltage turns on only when that particular Zone is on and turns off when the
zone is off.

RS-232 -

If you select RS-232, only an RS-232 command will turn on or off that zone's Control Out.

Zone On -

The Control Out is on if the zone is on and off when zone is off. (This is Default).

Zone Active -

The Control Out will turn on only if the zone is on AND the CT Receiver can

detect an audio or video signal on the input the zone has selected.

Zone Off -

The Control Out will turn on only if the zone is off.

Selected Input -

The Control Out is on only if this input is selected (switched to) by the user and

the zone is powered on. Note that when this option is selected, the input check boxes are now active
(no longer grayed out). Check the box next to the inputs that are desired to turn the 12VDC Zone
Control Out on. The input does not have to have a A/V signal present in order for the 12VDC trigger to be on.

Headphone*:

Only Zone A allows you to set the Control Out to be triggered by Headphone mode. Setting the Zone A
Control Out to headphone enables you to connect an external Zone A power amp and still have it turn off
automatically when the user selects headphone mode from a keypad or remote which is controlling Zone A.

1

2

This manual is related to the following products: