beautypg.com

Ir emitter outputs, S for daisy-chain applications. see, S for ir routing. 1/8” (3.5mm) mini jack. see – B&K CT600 User Manual

Page 22: Ir flasher emitter output, Buffered outputs

background image

IR Emitter Outputs

B K

&

S

B

I M P LY

E T T E R !

18

IR Flasher Emitter Output

Each of the nine shared sources can be controlled from any zone in the system using the CT Receiver built in
IR routing circuitry. When the IR Flasher outputs are set to “selected input,” (Default) IR is routed from the
keypads in each zone to the corresponding source according to the input selected for that zone. This way
multiple identical sources can be controlled without changing the source's IR code. For the system to oper-
ate properly, an IR emitter connected to the IR output must correspond to the source input, i.e. IN 6 with IR 6.
The IR outputs are compatible with any standard 1/8” (3.5mm) miniature flasher/emitter from Niles, Xantech,
Elan, Sonance or Speakercraft, etc. The IR outputs operate at 5V and can supply up to 10mA of current
(475

Ω internal output resistance). Carrier frequency ranges from 32 kHz to 42kHz. Make sure to use IR

shields when working with multiple identical sources in the same rack.

A/V S OURCE INPUTS

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT O PEN

B&K Components, Ltd.

Made in the U.S.A.

www.bkcomp.com

IN

1

IN

1

BUFFERED A /V SOURCE OUTPUTS

ZONE LINE O UTPUTS

VOLTAGE

FM

ANTENNA

RF REMOTE IN

IN

2

IN

2

IN

3

IN

3

OUT

1

OUT

2

OUT

3

IN

4

IN

4

IN

5

IN

5

IN

6

IN

6

OUT

4

OUT

5

OUT

6

IN

7

IN

7

IN

8

IN

8

IN

9

IN

9

OUT

7

OUT

8

OUT

9

IR 1

IR 2

IR 3

IR 4

IR 5

IR 6

IR 7

IR 8

IN

A

IN

B

IN

C

OUT

A

OUT

B

OUT

C

IN

D

IN

E

IN

F

OUT

D

OUT

E

OUT

F

IR 9

AM ANTENNA

AC LINE

~

FUSE

CAUTION: FOR CONTINUED

PROTECTION AGAINST RISK

OF FIRE REPLACE ONLY WITH

SAMETYPEAND VALUEFUSE

ZB

ZE

+12V

GND

RS232 XMIT

CTRL OUT

DATA IN

ZC

ZF

+12V

GND

RS232 XMIT

CTRL OUT

DATA IN

CONTROL

ZA

ZD

+12V

GND

RS232 XMIT

DATA IN

CTRL OUT

RIGHT

LEFT

+

-

+

-

ZONE F

RIGHT

LEFT

+

-

+

-

ZONE E

RIGHT

LEFT

+

-

+

-

ZONE D

RIGHT

LEFT

+

-

+

-

ZONE C

RIGHT

LEFT

+

-

+

-

ZONE B

RIGHT

LEFT

+

-

+

-

ZONE A

SPEAKER OUTPUTS

ARE 4 OHM STABLE

RS232

12V

GND

IN

-

OUT

IN +

12V

GND

IN

-

OUT

IN +

COMMON
CTRL I/O

The IR outputs are factory default set for selected input operation thus requiring the device input and IR out
to match. Simultaneous or “All Inputs” flash can be configured for the 9 IR outputs using either the OSD
menu or BKcSuite. When using matrix video switching (i.e. audio and video from different inputs), IR routing
will follow the audio input only for that zone.

Buffered Outputs

Line level, impedance matched, (buffered) out-
puts are provided in order to pass source signals
from one unit to another. Each of the 9 shared
A/V inputs has a buffered output. These outputs
are buffered in order to minimize signal degrada-
tion as the signal passes from unit to unit in
series. Essentially they can eliminate the need
for Y-cables. The Buffered outputs will primarily
be used for sharing of sources between other
whole house units or home theater systems.

CT610 #2

CT610 #1

Sources

This manual is related to the following products: