(9)

Signal isolation

Code 1

Code 2

Causes

90

01

Unable to detect video signals and commands within 6 seconds
after CFR is transmitted.

90

02

Received PPS containing invalid page count or block count.

(10) Video signal reception

Code 1

Code 2

Causes

A0

03

Error correction sequence not terminated even at the final
transmission speed for fallback.

A0

11

Receive buffer empty. (5-second time-out)

A0

12

Receive buffer full during operation except receiving into memory.

A0

13

Decoding error continued on 500 lines.

A0

14

Decoding error continued for 10 seconds.

A0

15

Time-out: 5 seconds or more for one-line transmission.

A0

16

RTC not found and carrier OFF signal detected for 6 seconds.

A0

17

RTC found but no command detected for 60 seconds.

A0

18

Receive buffer full during receiving into memory.

A8

01

RTN, PIN, or ERR received at the calling terminal.*

A9

01

RTN, PIN, or ERR received at the called terminal.*

* Available in Germany and Austria only

(11) General communications-related

Code 1

Code 2

Causes

B0

02

Unable to receive the next-page data.

B0

03

Unable to receive polling even during turn-around transmission
due to call reservation.

B0

04

PC interface error.