beautypg.com

Wsw24 tad setting 2 v-37 – Brother FAX-921 User Manual

Page 130

background image

V - 37

WSW24

(TAD setting 2)

Selector

No.

Function

Setting and Specifications

1

2

Maximum OGM recording time

No.

1

2

0

0

:

15 sec.

0

1

:

20 sec.

1

0

:

30 sec.

1

1

:

50 sec.

3

4

Time length from CML ON to
start of pseudo ring backtone
transmission

No.

3

4

0

0

:

4 sec.

0

1

:

3 sec.

1

0

:

2 sec.

1

1

:

1 sec.

5

|

8

Attenuator for playback of ICM/
OGM to the line
(Selectable from the range of 0-
15 dB)

0:

0 dB

1:

8 dB

0:

0 dB

1:

4 dB

0:

0 dB

1:

2 dB

0:

0 dB

1:

1 dB

NOTE: Selectors 1 and 2 are applicable to those models equipped with a built-in TAD.

l

Selectors 1 and 2: Maximum OGM recording time

These selectors set the allowable maximum recording time for an OGM.

l

Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission

These selectors set the length of time from CML-ON up to the start of pseudo ring backtone
transmission.

In those versions which have an OGM facility, the settings made by these selectors also apply to
the length of time from CML-ON up to the start of OGM transmission.

l

Selectors 5 through 8:

Attenuator for playback of ICM/OGM to the line

Setting two or more selectors to "1" produces addition of attenuation assigned to each selector.

This setting will not be limited by selector 8 of WSW23.

This manual is related to the following products: