Wsw24 tad setting 2 v-37 – Brother FAX-921 User Manual
Page 130
V - 37
WSW24
(TAD setting 2)
Selector
No.
Function
Setting and Specifications
1
2
Maximum OGM recording time
No.
1
2
0
0
:
15 sec.
0
1
:
20 sec.
1
0
:
30 sec.
1
1
:
50 sec.
3
4
Time length from CML ON to
start of pseudo ring backtone
transmission
No.
3
4
0
0
:
4 sec.
0
1
:
3 sec.
1
0
:
2 sec.
1
1
:
1 sec.
5
|
8
Attenuator for playback of ICM/
OGM to the line
(Selectable from the range of 0-
15 dB)
0:
0 dB
1:
8 dB
0:
0 dB
1:
4 dB
0:
0 dB
1:
2 dB
0:
0 dB
1:
1 dB
NOTE: Selectors 1 and 2 are applicable to those models equipped with a built-in TAD.
l
Selectors 1 and 2: Maximum OGM recording time
These selectors set the allowable maximum recording time for an OGM.
l
Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission
These selectors set the length of time from CML-ON up to the start of pseudo ring backtone
transmission.
In those versions which have an OGM facility, the settings made by these selectors also apply to
the length of time from CML-ON up to the start of OGM transmission.
l
Selectors 5 through 8:
Attenuator for playback of ICM/OGM to the line
Setting two or more selectors to "1" produces addition of attenuation assigned to each selector.
This setting will not be limited by selector 8 of WSW23.