Wsw10 protocol definition 2 v-23 – Brother FAX-921 User Manual
Page 116
V - 23
WSW10
(Protocol definition 2)
Selector
No.
Function
Setting and Specifications
1
Switching of DPS, following the
CML ON/OFF
0: No
1: Yes
2
Time length from transmission of
the last dial digit to CML ON
0: 100 ms
1: 50 ms
3
Time length from CML ON to CNG
transmission
0: 2 sec.
1: 4 sec.
4
Time length from CML ON to CED
transmission (except for facsimile-
to-telephone switching)
0: 0.5 sec.
1: 2 sec.
5
6
No. of training retries
No.
5
6
0
0
:
1 time
0
1
:
2 times
1
0
:
3 times
1
1
:
4 times
7
8
Not used.
l
Selector 1:
Switching of DPS, following the CML ON/OFF
Setting this selector to "1" automatically switches DPS following the CML ON/OFF operation.
l
Selector 2:
Time length from transmission of the last dial digit to CML ON
This selector sets the time length from when the equipment transmits the last dial digit until the
CML relay comes on.
l
Selector 3:
Time length from CML ON to CNG transmission
This selector sets the time length until the equipment transmits a CNG after it turns on the CML
relay.
l
Selector 4:
Time length from CML ON to CED transmission
This selector sets the time length until the equipment transmits a CED after it turns on the CML
relay. This setting does not apply to switching between facsimile and telephone.
l
Selectors 5 and 6: No. of training retries
These selectors set the number of training retries to be repeated before automatic fallback.