Symptom
Cause
Solution
Machine
power is not
on.
The power cord is not
correctly plugged into
the outlet.
Turn off the machine, confirm that the
power cord is correctly plugged into
the outlet, and then turn on the
machine.
Something is wrong
with the outlet con-
nected to the
machine.
Plug another electrical appliance into
the outlet and see whether it operates
properly.
The power switch is
not correctly turned
on (I position).
Turn the power switch off (O position),
then turn it back to the on (I position).
The machine is con-
nected to an outlet
with a voltage or fre-
quency that does not
match the machine
specifications.
Use a power source with the specifica-
tions listed in appendix A, “Technical
Specifications.”
The control
panel dis-
plays
TONER
LOW
much
sooner than
expected.
One of the toner car-
tridges may be defec-
tive.
Remove the toner cartridges and
check for damage. If it is damaged,
replace it.
You printed with
heavy toner cover-
age.
See specifications in Appendix A.
You can’t
print the
machine sta-
tus list.
The tray is empty.
Check that at least Tray 1 is loaded
with media, in place, and secure.
The machine’s cov-
ers aren’t closed
securely.
Make sure the covers are closed
securely. Close all covers gently to
avoid jarring the machine.
There is a media mis-
feed.
Clear the media misfeed.
Images can-
not be
printed from
the digital
camera.
The digital camera
transfer mode is not
set to PictBridge.
Set the digital camera transfer mode to
PictBridge.
"
The machine supports only
PictBridge-enabled digital
camera.