1.43.4
IEEE802.1x Authentication Setting
In the administrator mode of PageScope Web Connection, select the "Network" tab - "IEEE802.1x
Authentication Setting".
Configure the following settings.
Item
Definition
Prior confirmation
Authentication Status
The authentication status is shown as follows.
- Authenticated: The authentication process has finished.
- Authenticating: The authentication process is in progress.
- Unauthenticated: Not authenticated status.
- Authentication Failed: The authentication process has
failed.
When you press [Refresh], the authentication status is up-
dated.
IEEE802.1x Authentica-
tion Setting
Select "ON".
User ID
Enter a user ID (up to 128 characters).
This user ID is used for all EAP-Type options.
Password
Enter the password (up to 128 characters).
The password is used for all EAP-Type options other than
"EAP-TLS".
EAP-Type
Select an EAP authentication method.
If you select "Depend on Server", the EAP-Type provided by
the authentication server will be used for authentication.
Configure the supplicant settings as required for this ma-
chine according to the EAP-Type provided by the authenti-
cation server.
Do not set this item to "OFF".
EAP authentication
method
EAP-TTLS Internal Au-
thentication
Configure settings for EAP-TTLS.