ATTO Technology Diamond Storage Array S-Class User Manual
Page 89

78
4
Copy the latest Diamond Storage Array image
file (“...”.ima) onto the host computer and note
its directory
c:\diamond\flash\
“...”.ima
5
Change directories to the place where you
copied the “...”.ima file
cd c:\diamond\flash
6
Open an FTP session using a user-defined IP
address or the default (10.0.0.1) if it has not
changed. The IP address must be a valid
address for your network.
7
At the FTP login prompt, type sysadmin as the
userID.
8
Press return at the password prompt.
9
Type put “...”.ima
.
The Diamond should acknowledge receiving the
file and display a message not to interrupt power
for 90 seconds.
10 If upgrading the firmware from versions older
than 2.5.3, follow the procedures outlined in
11 When the flash procedure is complete, cycle
power on the array.
CAUTION
CAUTION
Do not interrupt the flash process. If the
process is interrupted, the Diamond
Storage Array will become inoperable and
will have to be returned to the factory for
repair.
Do not turn off the Diamond Storage
Array until the display returns the
Ready
prompt.