ATTO Technology Diamond Storage Array S-Class User Manual
Page 35

24
Ethernet access
4
Type
set SNMPUpdates enabled
5
Type
set SNMPTraps enabled
6
Type SaveConfiguration restart to reboot the
array.
7
Install SNMP management software on each
client you wish to receive traps (messages).
8
Call technical support (refer to
on page viii) to get the
appropriate MIB file for your array.
9
For each client, copy the MIB file to the
directory containing the SNMP management
software.
10 From within the SNMP management software,
compile the file
attodmnd-mib.mib
according to
the software’s procedures.
11 Unload any default MIBs.
12 Load the Diamond MIB ATTODIAMOND
.
13 When requested, enter the array’s IP address
as the Remote SNMP Agent.
14 The SNMP management software will contact
the agent in the array. The screen will reply with
system information.
15 Status will be monitored and reported through
the SNMP management software.
Traps are generated for the following situations
• Temperature status changes in any of the
sensors located on the array mid-plane.
• A drive or a sled is physically removed from the
array or put into the array.
• The power supply is turned on or off.
• The fan is physically stopped.