Program port commands (cont.) – AMX NETLINX MASTER NXC-ME260 User Manual
Page 22
Programming
18
NXC-ME260 NetLinx Master-Ethernet Card/Module
Program Port Commands (Cont.)
Command
Description
PASS
Sets up a pass through mode to a device. In pass through mode, any
string received by the device is displayed on the screen, and anything
typed is sent as a string to the device. The device can be on any system
the Master you are connected to can reach. You can specify the device
number, port, and system, or the name of the device that is defined in the
DEFINE_DEVICE section of the program.
Example:
>pass[5001:7:4]
Entering pass mode.
To exit pass mode, type + + esc esc.
PING
Tests network connectivity to and confirms the presence of another net-
worked device. The syntax is just like the PING application in Windows or
Linux.
Example:
>ping 192.168.21.209
192.168.21.209 is alive.
PROGRAM INFO
Displays the name of the NetLinx program residing in the Master Card.
Example:
>PROGRAM INFO
-- Program Name Info
-- Module Count = 1
1 Name is i!-PCLinkPowerPointTest
-- File Names = 2
1 = C:\Program Files\AMX Applications\i!-PCLinkPowerPoint
2 = C:\Program Files\Common Files\AMXShare\AXIs\NetLinx.axi
2 = Name is MDLPP
-- File Names = 2
1 C:\AppDev\i!-PCLink-PowerPoint\i!-PCLinkPowerPointMod.axs
2 C:\Program files\Common Files\AMXShare\AXIs\NetLinx.axi
PULSE channel> Pulses a channel on a device on and off. The device can be on any system Example: >PULSE[50001:8:50,1] Sending Pulse[50001:8:50,1] REBOOT Reboots the Master Card or specified device. Example: >REBOOT [0:1:0] Rebooting... RELEASE DHCP Releases the DHCP setting for the Master Card. Example: >RELEASE DHCP The Master must be rebooted to acquire a new DHCP lease.
the Master you are connected to can reach. You can specify the device
number, port, and system; or the name of the device that is defined in the