1 voltage sag & current fault duration registers, 2 voltage sag & current fault level registers, Cs5463 – Cirrus Logic CS5463 User Manual
Page 36: 3 page 3 registers

CS5463
36
DS678F3
6.3 Page 3 Registers
6.3.1 Voltage Sag and Current Fault
Duration
Registers ( VSAG
Duration
, ISAG
Duration
)
Address: 6 (Voltage Sag Duration); 10 (Current Fault Duration)
Default = 0x000000
Voltage Sag Duration (VSAG
Duration
) and Current Fault
Duration
(ISAG
Duration
)
defines the number of instanta-
neous measurements utilized to determine a sag event. Setting these register to zero will disable this feature.
The value is represented in unsigned notation. See Section 5.6
6.3.2 Voltage Sag and Current Fault Level Registers ( VSAG
Level
, ISAG
Level
)
Address: 7 (
Voltage Sag Level
); 11 (
Current Fault Level
)
Default = 0x000000
Voltage Sag Level (VSAG
Level
) and Current Fault Level (ISAG
Level
) defines the voltage level that the magnitude
of input samples, averaged over the sag duration, must fall below in order to register a sag/fault condition. These
value are represented in unsigned notation and in the range of 0
VSAG
Level
1.0, with the binary point to the
right of the third MSB. See Section 5.6
MSB
LSB
0
2
22
2
21
2
20
2
19
2
18
2
17
2
16
.....
2
6
2
5
2
4
2
3
2
2
2
1
2
0
MSB
LSB
0
2
-1
2
-2
2
-3
2
-4
2
-5
2
-6
2
-7
.....
2
-17
2
-18
2
-19
2
-20
2
-21
2
-22
2
-23