beautypg.com

1 voltage sag & current fault duration registers, 2 voltage sag & current fault level registers, Cs5463 – Cirrus Logic CS5463 User Manual

Page 36: 3 page 3 registers

background image

CS5463

36

DS678F3

6.3 Page 3 Registers

6.3.1 Voltage Sag and Current Fault

Duration

Registers ( VSAG

Duration

, ISAG

Duration

)

Address: 6 (Voltage Sag Duration); 10 (Current Fault Duration)

Default = 0x000000

Voltage Sag Duration (VSAG

Duration

) and Current Fault

Duration

(ISAG

Duration

)

defines the number of instanta-

neous measurements utilized to determine a sag event. Setting these register to zero will disable this feature.
The value is represented in unsigned notation. See Section 5.6

Sag and Fault Detect Feature

on page 19.

6.3.2 Voltage Sag and Current Fault Level Registers ( VSAG

Level

, ISAG

Level

)

Address: 7 (

Voltage Sag Level

); 11 (

Current Fault Level

)

Default = 0x000000

Voltage Sag Level (VSAG

Level

) and Current Fault Level (ISAG

Level

) defines the voltage level that the magnitude

of input samples, averaged over the sag duration, must fall below in order to register a sag/fault condition. These
value are represented in unsigned notation and in the range of 0

 VSAG

Level

 1.0, with the binary point to the

right of the third MSB. See Section 5.6

Sag and Fault Detect Feature

on page 19.

MSB

LSB

0

2

22

2

21

2

20

2

19

2

18

2

17

2

16

.....

2

6

2

5

2

4

2

3

2

2

2

1

2

0

MSB

LSB

0

2

-1

2

-2

2

-3

2

-4

2

-5

2

-6

2

-7

.....

2

-17

2

-18

2

-19

2

-20

2

-21

2

-22

2

-23