Electrical data

Power supply U

B

DC 12 ≤ UB ≤ 30 V

Influence of power supply

≤ 0.1 % of full scale value/10 V

Permissible residual ripple

≤ 10 % ss

Output signal, variant I

4 … 20 mA, 2-wire, passive, per NAMUR NE43

Permissible max. load RA

RA ≤ (UB - 12 V)/0.02 A with RA in Ω and UB

in V, however max. 600 Ω

Effect of load

≤ 0.1 % of FS

Output signal, variant II

0 ... 10 V

Impedance at voltage output

0.5 Ω

Load capacity at voltage output 2 … 100 kΩ
Sensor sampling rate

600 ms

Linearity

≤ 1.0 % of span (limit point setting)

Output signal accuracy

0.2 % of FS (electronics only)

Resolution

0.15 % of FS (10 bit resolution at 360°)

Refresh rate (measuring rate)

> 1/s

Input signal, angle of rotation

0 … 270 ∢ °

Long-term stability of electronics < 0.3 % of FS/a
Temperature error, electronics

< 0.3 % of FS/10 K (in overall temperature

range)

Warm-up time

≤ 5 min

Permissible ambient temperature 0 ... 40 °C

Permissible storage temperature -40 … +70 °C without liquid damping

-20 … +70 °C with liquid damping

Electromagnetic compatibility

(EMC)

EMC directive 2004/108/EC, EN 61326

emission (group 1, class B) and interference

immunity (industrial application)

Electrical connection

via angular connector, 180°

rotatable, max. 1,5 mm², cable

protection, M20 x 1.5 cable gland,

cable outer diameter 7 ... 13 mm,

incl. strain relief

Ingress protection

IP 65 to IEC 60529

Protection against reverse polarity and

overvoltage

3. Specifications