WIKA operating instructions models PGS10, PGS11 and PGS21

12

5. Electrical switch contacts / 6. Transport, packaging ...

Switch point adjustment (models PGS10 and PGS11)
To adjust the switch point, carefully loosen the window using a screwdriver.

The contact (red mark pointer) can then be set to the desired position by

hand. It can be set between 10 % and 90 % of the full scale value.

Afterwards, lightly push the window back into the case.

15 % FSV

10 % F

SV

31023461.01

10 % F

SV

6. Transport, packaging and storage

6.1 Transport

Check pressure gauge for any damage that may have been caused by

transport.

Obvious damage must be reported immediately.

6.2 Packaging

Do not remove packaging until just before mounting.

Keep the packaging as it will provide optimum protection during transport

(e.g. change in installation site, sending for repair).

Adjustability of

contacts

If the switch point of the instruments approved by VdS is changed

by the customer, the customer will lose the VdS approval.