beautypg.com

WIKA PGS21 User Manual

Page 11

background image

WIKA operating instructions models PGS10, PGS11 and PGS21

11

5. Electrical switch contacts

Index Designa-

tion

Symbol

Switching function / setting

direction

Code

1

Normally

open

(NO)

Contact makes with rising pressure or

clockwise pointer motion (standard)

1

Contact breaks with falling pressure or

anticlockwise pointer motion

5

2

Normally

closed

(NC)

Contact breaks with rising pressure or

clockwise pointer motion (standard)

2

Contact makes with falling pressure or

anticlockwise pointer motion

4

12

Normally

open /

closed

(NO-NC)

See switching function or setting

direction for single contact

11

Normally

open /

open

(NO-NO)

See switching function or setting

direction for single contact

22

Normally

closed /

closed

(NC-NC)

See switching function or setting

direction for single contact

Magnetic snap-action contact (normally closed or normally open)
The instruments are delivered with a single or double contact (normally

closed or normally open).
With 'normally closed', the contact flag is engaged with the limit switch and,

on rising pressure, disengages from the contact via the actuator attached to

the pointer. The circuit will be interrupted.

With 'normally open' the contact flag follows the pointer until the limit value

is reached. Once the limit value has been exceeded, the contact flag

engages and the circuit is closed.
The switching function of the switch is indicated by the index 1, 2, 12, 11

or 22.

11581752.02 09/2013 GB/D/F/E

GB

This manual is related to the following products: