beautypg.com

Specifications – WIKA S-11 User Manual

Page 14

background image

14

WIKA operating instructions pressure transmitter, model S-11

GB

14043046.01 06/2012 GB/D/F/E

3.7 Process connections

Process connection

Available measuring ranges

G ½ B flush

1)

0 ... 2.5 to 0 ... 600 bar

G 1 B flush

1)

0 ... 0.1 to 0 ... 1.6 bar

Hygienic G 1 B flush

0 ... 0.1 to 0 ... 25 bar

3.8 Materials
Wetted parts

Stainless steel

For sealing materials see table

Process connection

Standard

Option

without cooling element

NBR

FPM/FKM

EPDM

with cooling element

FPM/FKM

EPDM

Hygienic

EPDM

-

Non-wetted parts

Internal system fill fluid

Standard: Synthetic oil

Option:

Food-compatible system fill fluid per FDA 21 CFR 178.3750

3.9 Approvals, directives and certificates
Approval

CSA

GOST

3. Specifications