8 Supplement

WIKA Operating instructions - Submersible pressure transmitter model LH-20

Measuring ranges

Overload capacity, max. pressure

0 … 2.5 bar

50 bar

0 … 4 bar

65 bar

0 … 6 bar

90 bar

0 … 10 bar

90 bar

0 … 16 bar

130 bar

0 … 25 bar

130 bar

Output variable 4 … 20 mA
Output signal

4 … 20 mA

Signal resolution

4 µA

Fault signal

22 mA

Max. output current

22 mA

Run-up time

Ʋ with deviation ≤ 0.2 % approximately 2 s

Ʋ with deviation ≤ 0.1 % approximately 15 s

Output variable 4 … 20 mA/HART (optional)
Output signal

4 … 20 mA/HART

HART output values according to HART standard 5.0

Ʋ Primary Value

Pressure

Ʋ Secondary Value

Temperature

Signal resolution

1 µA

Fault signal

< 3.6 mA

Max. output current

22 mA

Run-up time approx.

15 s

Additional output parameter - temperature (optional)
Integrated resistance thermometer

Pt 100 according to DIN EN 60751

Tolerance class

B

Range

-50 … +100 °C (-58 … +212 °F)

Reference conditions and actuating variables (according to DIN EN 60770-1)
Reference conditions according to DIN EN 61298-1

Ʋ Temperature

+15 … +25 °C (+59 … +77 °F)

Ʋ Relative humidity

45 … 75 %

Ʋ Air pressure

860 … 1060 mbar/86 … 106 kPa (12.5 … 15.4 psig)

Determination of characteristics

Limit point adjustment according to IEC 61298-2

Characterstic curve

Linear

Reference installation position

upright, diaphragm points downward

Influence of the installation position

< 0.2 mbar/20 Pa (0.003 psig)