9 communication parameters, Communication parameters, 9communication parameters – Kramer Electronics VP-4x4K User Manual
Page 40

36
VP-4x4K - Communication Parameters
9
Communication Parameters
VP-4x4K communication parameters are listed here.
EDID
EDID data is passed between Input 1 and Output 1
RS-232
Protocol 2000
Protocol 3000 (Default)
Baud Rate:
9600
Baud Rate:
115,200
Data Bits:
8
Data Bits:
8
Stop Bits:
1
Stop Bits:
1
Parity:
None
Parity:
None
Command Format:
HEX
Command
Format:
ASCII
Example (Output 1 to
Input 1):
0x01, 0x81, 0x81,
0x81
Example (Output
1 to Input 1):
#AV 1>1
Switching Protocol
P2000 -> P3000
P3000 -> P2000
Command:
0x38, 0x80, 0x83,
0x81
Command:
#P2000
Front Panel:
Press and hold
Output 1 and
Output 3
simultaneously
Front Panel:
Press and hold
Output 1 and
Output 2
simultaneously
Ethernet
Default Settings
Reset Settings
IP Address: 192.168.1.39 Power cycle the unit while holding in the Factory Reset button,
located on the rear panel of the unit.
TCP Port #: 5000
UDP Port #: 50000