5.4
Cascading Machines
You can cascade up to 16
VP-4x4K units with control from a PC or serial
controller.
To cascade 16 individual
VP-4x4K units via RS-485, as illustrated in the example
in
, do the following:
1. Connect the sources and acceptors (see
Section 5.1
2. Connect the RS-232 port of the first
VP-4x4K unit to a PC.
3. Connect the RS-485 terminal block port on the first
VP-4x4K unit to the
RS-485 port on the second
VP-4x4K unit and so on, connecting all the
RS-485 ports.
4. Set the first
VP-4x4K unit as Machine # 1 and the following VP-4x4K units
as Machine # 2 to Machine # 16 (see
Section 6.4
5. On the first and last
VP-4x4K units, set the RS-485 TERM DIP-switch to ON,
terminating the RS-485 line at 120Ω (see
Section 5.6
), and set this DIP-
switch to OFF on the other
VP-4x4K units.
- VM-216H (25 pages)
- VM-28H (23 pages)
- VM-22H (12 pages)
- VM-24H (23 pages)
- VM-24HC (21 pages)
- VM-24HD (10 pages)
- VM-24HDCP (19 pages)
- VM-42 (8 pages)
- VP-222K (10 pages)
- VP-242 (8 pages)
- VP-32K (13 pages)
- VS-202YC (23 pages)
- 4x1S (15 pages)
- 4x1V (12 pages)
- 6241HDxl (10 pages)
- 6241N (10 pages)
- 6502 (12 pages)
- PT-201VGA (8 pages)
- TailorMade (21 pages)
- TailorMade (22 pages)
- VP-1201 (50 pages)
- VP-12x8 (34 pages)
- VP-1608 (46 pages)
- VS-88SDI (42 pages)
- VP-321xl (37 pages)
- VP-16x18AK (60 pages)
- VP-201xl (8 pages)
- VP-211K (15 pages)
- VP-27 (32 pages)
- VS-66HN (25 pages)
- VS-88HDxl (43 pages)
- VP-28 (42 pages)
- VP-2x2 (17 pages)
- VP-31 (25 pages)
- VP-311DVI (20 pages)
- VS-88HD (21 pages)
- VS-88HD (44 pages)
- VP-31KSi (16 pages)
- VP-81KSi (51 pages)
- VP-31KSi (48 pages)
- VP-41 (8 pages)
- VP-411DS (22 pages)
- VS-81HDxl (25 pages)
- VP-4x1CS (39 pages)