Storing an Input/Output Configuration
To store the current status in memory, do the following:
1. Press the STO button.
The STO button flashes.
2. Press one of the 12 INPUT/OUTPUT buttons (the setup # of the current
status). If in the Confirm mode, press the flashing TAKE button to confirm
the action.
The memory stores the data at that reference.
6.3.2
Recalling an Input/Output Configuration
To recall an input/output configuration, do the following:
1. Press the RCL button.
The RCL button flashes.
2. Press the appropriate INPUT/OUTPUT button (the button # corresponding to
the setup #). If in the Confirm mode, that setup configuration flashes in the
7-segment display, together with the RCL button and the TAKE button, and
is only implemented after pressing the TAKE button.
The memory recalls the stored data from that reference.
Tip: If you cannot remember which input/output configuration is the
one that you want, set to the Confirm mode and manually scan all the
input/output configurations until you locate it.
6.3.3
Deleting an Input/Output Configuration
To delete an input/output configuration, do the following:
1. Press the STO and RCL buttons simultaneously.
Both the STO and RCL buttons flash.
2. Press the appropriate INPUT/OUTPUT button.
This erases that specific input/output configuration from the memory, leaving
it empty and available.
Storing a new configuration over a previous configuration (without deleting it first)
replaces the previous configuration