1 spc11 parameters – Festo Контроллер крайних положений SPC11 User Manual
Page 29
2. Parameters of the SPC11 for the DGCI or DDLI
2-3
Festo P.BE-SPC11-DGCI-EN en 1406d
2.1
SPC11 parameters
Warning
Incorrectly set parameters can damage the fixed stops and
the drive.
Be very careful when setting the parameters.
The SPC11 must be familiar with certain conditions of use.
These conditions of use are described by the following three
parameters, which must be entered directly on the SPC11:
Parameters
Description
Amplification stage
Influences the acceleration behaviour of the
drive
Cushioning stage
Influences the retracting behaviour when
moving to the end positions and intermedi-
ate positions.
System parameters
Characteristic value for the structure of the
drive
You can set the parameters with the buttons on the SPC11
(see System Manual). Valid parameters for operating the
SPC11 with drive type DGCI/DDLI can be found in section 2.3.
These parameters are matched exactly to the specified com-
binations of drives, valves and mass loads.