2 system structure with the dgci or ddli – Festo Контроллер крайних положений SPC11 User Manual
Page 16
1. Installation instructions for the DGCI or DDLI
1-4
Festo P.BE-SPC11-DGCI-EN en 1406d
1.2
System structure with the DGCI or DDLI
The following diagram shows the basic layout of a drive with
the SPC11 using as an example drive type DGCI-... .
1
2
4
5
3
6
2
7
1
Drive (here type DGCI-... with built-on
measuring system)
2
Fixed stop (here e.g. B. KYC-...)
3
Measuring system connection
4
SPC11-MTS-AIF-2
5
Proportional directional control valve
type MPYE-5-...-010B
6
Service unit with 5 µm filter, without
lubricator
7
Compressed air source (5 to 7 bar)
Fig. 1/1:
System structure of the SPC11