SLG−...

Festo SLG−... 0802d English

27

S

Tighten the one−way flow control valves:

ć at first completely
ć then loosen again approximately one

turn.

S

Pressurize the component as follows:

ć First pressurize both sides and
ć then one side. The slide will then move into an end position. In this way you

will avoid overloading the component and the compressed air network.

S

Start a test run.

During the test run:

S

check whether modifications are required to the following settings:

ć the speed of the moving mass (restrictor settings)
ć the position of the end stops (rough and accurate settings).

With masses which project longitudinally over
the slide

S

Interrupt the test run while you are operĆ
ating the locking screws of the end stops.

S

Open the one−way flow control valves
slowly until the desired slide speed is
reached.

S

Conclude the test run.

Fig. 23