beautypg.com

5 fitting, Fig. 6 mechanical fitting, 5fitting – Festo Пневматические линейные приводы SLG User Manual

Page 22

background image

SLG−...

Festo SLG−... 0802d English

22

5

Fitting

Mechanical fitting

S

Prevent the sealing band from being
pressed or sucked in.
Damage to the sealing band reduces the
operating reliability.
A sudden jerk movement of the pressureĆ
less slide can create a low pressure which sucks the sealing band into the
piston chamber.

S

Place the component in position with reĆ
gard to the following points:

ć You must be able to gain access to the

operating parts and connections later
when the component is installed.

ć The fitting position takes into account

the minimum distances required for
reliable operation of the proximity
switches used.

L

1

L

2

= L

3

L

4

L

5

(SME−10−...)

(SMT−10−...)

L

1

L

5

SLG−8−...

as desired

10 mm

17 mm

4 mm

SLG−12−...

12 mm

as desired

SLG−18−...

46 mm

26 mm

Fig. 8

If the minimum distances are not observed, an individual functional check may
be necessary.

Fig. 6

Fig. 7