5 fitting, Fig. 6 mechanical fitting, 5fitting – Festo Пневматические линейные приводы SLG User Manual
Page 22
SLG−...
Festo SLG−... 0802d English
22
5
Fitting
Mechanical fitting
S
Prevent the sealing band from being
pressed or sucked in.
Damage to the sealing band reduces the
operating reliability.
A sudden jerk movement of the pressureĆ
less slide can create a low pressure which sucks the sealing band into the
piston chamber.
S
Place the component in position with reĆ
gard to the following points:
ć You must be able to gain access to the
operating parts and connections later
when the component is installed.
ć The fitting position takes into account
the minimum distances required for
reliable operation of the proximity
switches used.
L
1
L
2
= L
3
L
4
L
5
(SME−10−...)
(SMT−10−...)
L
1
L
5
SLG−8−...
as desired
10 mm
17 mm
4 mm
SLG−12−...
12 mm
as desired
SLG−18−...
46 mm
26 mm
Fig. 8
If the minimum distances are not observed, an individual functional check may
be necessary.
Fig. 6
Fig. 7