Distance tables – Muxlab Passive CCTV/GLI Hub User Manual
Page 17

© MuxLab Inc.
Passive CCTV/GLI Hub Installation Guide
Page 17
5.
Distance Tables
The following tables provide the maximum distances for remote
power via Cat5 twisted pair when a port on the Passive CCTV/GLI
Hub is set to Pass-Thru Mode (500022) or Power-Thru Mode
(500024/500029).
Pass-Thru Mode (500022) – Two (2) Twisted Pairs
Voltage
Pcam
(W)
Vcam
1
min (V)
Dist Spec
2
max (Feet)
Dist Spec
2
max (m)
5
10.80
86
28
10
10.80
43
14
12 VDC/AC PSU
12VDC/AC camera
20
10.80
22
7
5
21.60
346
113
10
21.60
173
57
24 VAC PSU
24VAC camera
20
21.60
86
28
5
21.60
922
302
10
21.60
461
151
28 VAC PSU
24VAC camera
20
21.60
230
76
Power-Thru Mode (500024/500029) – Three Twisted
Pairs
Voltage
Pcam
(W)
Vcam
1
min (V)
Dist Spec
2
max (Feet)
Dist Spec
2
max (m)
5
10.80
130
43
12 VDC/AC PSU
12VDC/AC camera
10
10.80
65
21
5
21.60
518
170
10
21.60
259
85
24 VAC PSU
24VAC camera
20
21.60
130
43
5
21.60
1382
454
10
21.60
691
227
28 VAC PSU
24VAC camera
20
21.60
346
113
Notes:
1.
Distances are specified for temperatures of 20
o
C to 30
o
C
2.
Maximum distances based on 10% loss of voltage. For 28VAC, a 24VAC camera was
used.
3.
Distances specified are 90% of distances calculated.
4.