Configuring the settings, Onnect to, River – RMS Technologies IMDP 23 W/ POLE DAMPING TECHNOLOGY*NEW* User Manual
Page 16: For setting, Arameters

RMS Technologies
Page 16
Version 1.04
IMDP23/IMDEP23 Manual
8/4/2010
7
Configuring The Settings
Connect to RMS Driver GUI for setting Parameters
Download the RMSDriver.zip file from the IMDP23 webpage.
Connect to your PC, and turn on the Power Supply.
Figure 19: GUI
Setting
Values
Description
Full step, 2x, 4x,
5x, 8x, 10x, 16x,
25x, 32x, 50x, 64x,
125x, 128x, 250x,
or 256x.
MicroStep: Changes the step resolution such
that the motor will step in smaller increments.
This helps with smooth and quiet operation.
0 to 6350 msec, in
50 msec
increments
1000 msec = 1 sec
Hold current delay time: This setting is a time
delay in milliseconds. After the last step pulse
is sent to the motor, there will be a delay time
for when the motor switches from run to hold
current. This can be beneficial if moving a
large load that needs high current during 1 or
2 seconds after a move is completed, but
beyond this, you may want to hold the unit
using less power.
Select the COM port
and click “Connect”
1
2
3
Make changes to
current,
microstepping,
etc.
Click “Program”
to store the
settings.