Configuring The Settings
 
Connect to RMS Driver GUI for setting Parameters 
 
Download the RMSDriver.zip file from the IMDP23 webpage. 
 
Connect to your PC, and turn on the Power Supply. 
 
Figure 19: GUI
 
 
 
 
 
 
Setting
Values
Description
Full step, 2x, 4x, 
5x, 8x, 10x, 16x, 
25x, 32x, 50x, 64x, 
125x, 128x, 250x, 
or 256x. 
MicroStep: Changes the step resolution such 
that the motor will step in smaller increments. 
This helps with smooth and quiet operation. 
0 to 6350 msec, in 
50 msec 
increments 
 
1000 msec = 1 sec 
Hold current delay time: This setting is a time 
delay in milliseconds. After the last step pulse 
is sent to the motor, there will be a delay time 
for when the motor switches from run to hold 
current. This can be beneficial if moving a 
large load that needs high current during 1 or 
2 seconds after a move is completed, but 
beyond this, you may want to hold the unit 
using less power. 
Select the COM port
and click “Connect”
1
2
3
Make changes to 
current, 
microstepping, 
etc. 
Click “Program” 
to store the 
settings.