Using the gui software to set parameters, Sing the, Oftware to – RMS Technologies IMD 34 W/ POLE DAMPING TECHNOLOGY*NEW* User Manual
Page 18: Arameters

RMS Technologies
Page 18
Version 1.00
IMD34 / IMDE34 User Manual
4/28/2009
Example: 
#AFR 
show the firmware version
#ASR256
set the step resolution to 256 microstepping
#ARI5000 set the current to 5A peak
#ASD
Save data
 
Using the GUI Software to Set Parameters: 
If using the GUI interface, simply download the executable from the IMD34 webpage in the 
download section. Unzip the file. 
 
Figure 17: GUI
Upon opening the Driver GUI, a screen shown above will 
pop up. Select the “IMD34/IMDE34” Product, and click 
“Open”. 
 
• Address = command “MA”
• Micro-step = command “SR”
• Run Current = command “RI” 
• Hold Current = command “HI” 
• Percent Decay = command “PF”
• Step – rising sensing / falling sensing =
command “SS”
• Forward direction / Reverse direction = command
DR